In Vitro Evaluation of Horizontal Implant Micromovement in Bone Specimen With Contact Endoscopy
In Vitro Evaluation of Horizontal Implant Micromovement in Bone Specimen With Contact Endoscopy
March 2004
Engelke, Wilfried DrDrMed; Decco, Oscar A. DDS; Rau, Mar??a Jos?© DiplIng; Massoni, Mar??a Clara Acosta Bioing, Schwarzw?ßller, Wolfgang DrRerNat
Implant Dentistry: Volume 13(1) March 2004 pp 88-94
Please visit the web site to view the article in its entirety.
Abstract
Primary stability of dental implants is mandatory for their osseointegration. A method is described that allows objective measurements of implant displacement in bone sites during lateral loading. Ten samples of bovine bone (2 cm ?Û 2 cm) with bone type II, III, and IV according to Lekholm and Zarb were used for the experiment. Ten Semados dental implants of 15-mm length and 3.75-mm diameter were placed. All implants were loaded with lateral forces of 5, 10, 20, and 30 N through 8-mm abutments for 2 seconds each. Lateral displacement was observed by means of contact endoscopy. Micromovement was detected with the help of a transmitter strip attached to the abutment. Endoscopic images were processed digitally and microdis- placement was calculated relative to the reference body (microscrew) placed adjacent to the implant. Micromovement observed varied with the force applied. Lateral force of 5 N resulted in a mean displacement of 39 ¨µm; for 30 N, the mean displacement was 157 ¨µm. Bone type also influenced the amount of movement. Contact endoscopy represents a new method for direct observation of implant movement relative to the bone surface in vitro. In combination with support immersion technique, contact endoscopy could be used as an office procedure to evaluate intraoperatively implant stability during functional loading.
References
1. Sennerby L, Meredith N. Resonance frequency analysis: Measuring implant stability and osseointegration. Compendium. 1998; 19: 493-502.
2. Tscherne H, Trenz O. Allgemeine Frakturenlehre. In: Heberer G, K??le W, Tscherne H, eds. Chirurgie. Lehrbuch f??r
Studierende der Medizin und ?—rzte, 5th ed. Berlin; 1985.
3. Engelke W, Jacobs H. Cortical support for immediate loading of dental implants. Int Mag Oral Implantol. 2000; 1: 16-22.
4. Johansson CB, Albrektsson T. The Integration of screw implants in the rabbit. A 1 year follow up of removal torque of titanium implants. Int J Oral Maxillofac Implants. 1987; 2: 69-75.
5. Wennerberg A. On surface roughness and implant incorporation [Thesis]. G??teborg University; 1996.
6. Buser D, Nydegger T, Oxland T, et al. Interface shear strength of titanium implants with a sandblasted and acid-etched surface: A biomechanical study in the maxilla of miniature pigs. J Biomater Res. 1991; 25: 889-902.
7. Glauser R, Meredith N. Diagnostische M??glichkeiten zur Evaluation der Implantatstabilit?ßt. Implantologie. 2001; 2: 147-160.
8. Brunski BJ, Puelo DA, Nanci A. Biomaterials and biomechanics of oral and maxillofacial implants: Current state and future developments. Int J Oral Maxillofac Implants. 2000; 15: 15-46.
9. Engelke W. In situ evaluation of implant sites for risk factors with support immersion endoscopy. Int J Oral Maxillofac Implants. 2002; 17: 703-706.
10. Andrea M, Dias O, Santos A. Contact endoscopy of the vocal cords: Normal and pathological patterns. Acta Otolaryngol. 1995; 115: 314-316.
11. Andrea M, Dias O, Macor C, et al. Contact endoscopy of the nasal mucosa. Acta Otolaryngol. 1997; 117: 307-311.
12. Davies JE, Hosseini MM. Histodynamics of endosseous wound healing. In: Davies JE, ed. Bone Engineering. Toronto: Em Squared Inc; 2000: 7-9.
13. Brunski JB. In vivo bone response to biomechanical loading at the bone/dental-implant interface. Adv Dent Res. 1999; 13: 99-119.
14. Block MS, Kent JN. Endosseous Implants for Maxillofacial Reconstruction. Philadelphia: WB Saunders 1995: 223-250.
15. Balon BE. Pull-out strength of screw shaped dental implants in bovine cancellous bone [Thesis]. Rensselaer Polytechnic Institute. New York: Troy; 1993.
16. Rau MJ, Acosta Massoni MC. 'Observaci??n endosc??pica y medici??n de movimientos en implantes dentales' Proyecto Final de la carrera de Bioingenier??a-Facultad de Ingenier??a de la Universidad Nacional de Entre R??os (Argentina); 2002.
17. Engelke W, Hoch G. Simultaneous evaluation of articulatory velopharyngeal function under different dynamic conditions with EMA and video endoscopy. Folia Phoniatr Logop. 1996; 48: 65-77.
18. Engelke W. Messverfahren und Vorrichtung zur Bestimmung der Stabilit?ßt eines Implantates oder eines Zahnes. Deutsche Patentanmeldung. M??nchen; 2002.
Comments: 0
Votes:34