Immediate loading of hydroxyapatite-coated implants in the maxillary premolar area: Three-year results of a pilot study
Immediate loading of hydroxyapatite-coated implants in the maxillary premolar area: Three-year results of a pilot study
March 2004
By Periklis Proussaefs DDS, MS, and Jaime Lozada DDS
The Journal of Prosthetic Dentistry
You can view the abstract online. A subscription is required to view the full text or it can be purchased online.
Abstract
Statement of the problem
Although immediate loading of implants in the edentulous mandible has been described in the literature, there is limited information regarding immediate loading of single implants.
Purpose
This prospective clinical study evaluated the clinical parameters of immediately loaded single-threaded hydroxyapatite-coated (HA) root form implants.
Material and methods
Ten human subjects were included in this report. In all situations, a screw-retained provisional acrylic resin crown was placed in the maxillary premolar area immediately after implant surgery. Definitive screw-retained metal-ceramic prostheses were placed 6 months after surgery. Standardized periapical radiographs were made before implant surgery, immediately after surgery, and 1, 3, 6, 12, and 36 months after implant surgery. Mobility (measured with the Perio-Test), distance from implant platform to the gingival crevice, distance from the implant platform to the depth of the sulcus, peri-implant probing depth, and bleeding on probing index were recorded at 3, 6, 12, and 36 months after implant placement. For clinical measurements, a 5-mm healing abutment was placed.
Results
All implants appeared clinically osseointegrated. Standardized radiographs demonstrated mean marginal bone loss of 0.6, 0.7, 0.8, 0.9, and 1.0 mm at 1, 3, 6, 12, and 36 months after implant surgery, respectively. Mean implant mobility was -3.3 at the day of surgery and -3.8, -3.4, -3.6, and -4.2 at 3, 6, 12, and 36 months, respectively. The distance from implant platform to the gingival crevice was 2.8, 2.4, 2.4, and 3.1 mm at 3, 6, 12, and 36 months, respectively. The distance from the implant platform to the depth of the sulcus was 0.8, 0.9, 0.9, and 1.1 mm at 3, 6, 12, and 36 months, respectively. The peri-implant probing depth was 3.6, 3.3, 3.2, and 4.3 mm at 3, 6, 12, and 36 months, respectively. The bleeding on probing index was 0.4, 0.4, 0.4, and 0.1 at 3, 6, 12, and 36 months, respectively.
Conclusion
The results of this prospective pilot study provide initial evidence that single root form implants may be immediately loaded when placed at the maxillary premolar area.



Votes:9